Overview

With advanced microprocessor technology and state-of-the-art silicon pressure sensors, the Additel 160 series Intelligent Digital Pressure Module (IDPM) provides an accurate, reliable, and economic solution for wide range of pressure applications. It is loaded with functionality and remarkably easy to use. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure module for Additel 760 automatic handheld pressure calibrator, Additel 761 automated pressure calibrator and Additel 222A, Additel 223A  and Additel 761 calibrators, the Additel 160 IDPM is unmatched in performance and reliability.

 

Features

• Pressure ranges to 60,000 psi (4,200 bar)

• Precision accuracy to 0.01% RD

• Pressure measurement accuracy of 0.02% FS

• Fully temperature compensated accuracy

 

Applications

The 160A series Digital Pressure Modules (IDPM) are specially designed as external pressure module for 761 automated pressure calibrator, 222A Multifunction Process Calibrators and 223A Documenting Process Calibrators.

 

Specifications

Standard Accuracy Precision Accuracy
CPXXX GPXXX DPXXX APXXQ APXXR
Operating temperature -10°C to 50°C (14°F to 122°F) 15°C to 25°C (59°F to 77°F) 10°C to 30°C (50°F to 86°F)
Storage temperature -20°C to 70°C (-4°F to 158°F) -20°C to 70°C (-4°F to 158°F)
Relative humidity 95% RH 90% RH
Pressure connections (for external use only) 1/4NPT, 1/2NPT, 1/4BSP,  1/2BPS, M20x15 Festo 6mm 1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15
Enclosure (for external use only) SS enclosure
Dimensions (Dia x H) 33 mm x 123 mm (1.3” x 4.84”) Depends on the model 44 mm x 195 mm (1.7” x7.7”)
Weight 0.4 kg (0.99 lb) Depends on the model 0.7 kg (1.5 lb)
Warranty 1 Year 1 Year 1 Year

 

Gauge Pressure[1]
P/N Pressure Range Media[2] Accuracy (%FS) Burst Pressure
(inH2O) (mbar)
V15 -15 -1 G 0.02
GP2 2 0.16 G 0.05
GP5 5 0.35 G 0.05
GP10 10 0.7 G 0.02
GP15 15 1 G 0.02
GP30 30 2 G 0.02
GP50 50 3.5 G , L 0.02
GP100 100 7 G , L 0.02
GP150 150 10 G , L 0.02
GP300 300 20 G , L 0.02
GP500 500 35 G , L 0.02
GP600 600 40 G , L 0.02
GP1K 1000 70 G , L 0.02
GP2K 2000 140 G , L 0.02
GP3K 3000 200 G , L 0.02
GP5K 5000 350 G , L 0.02
GP10K 10000 700 G , L 0.02
GP15K 15000 1000 G , L 0.05 2x
GP20K 20000 1400 G , L 0.05 1.5x
GP25K 25000 1600 G , L 0.1 1.5x
GP30K 30000 2000 G , L 0.1 1.5x
GP36K 36000 2500 G , L 0.1 1.5x
GP40K 40000 2800 G , L 0.1 1.35x
GP50K 50000 3500 G , L 0.1 1.2x
GP60K 60000 4200 G , L 0.1 1.1x
[1]. Sealed gauge pressure for above 1000 psi [2]. G=Gas, L=Liquid

 

Differential Pressure
P/N Pressure Range[1] Media Accuracy (%FS) Burst Pressure Static Pressure Range
(inH2O) (mbar)
DP1 ±1 ±2.5 G 0.05[2] 100× ±10 psi
DP2 ±2 ±5.0 G 0.05[2] 100× ±10 psi
DP5 ±5 ±10 G 0.05[2] 50× ±10 psi
DP10 ±10 ±25 G 0.05[2] 20× ±10 psi
DP20 ±20 ±50 G 0.05 20× ±10 psi
DP30 ±30 ±75 G 0.05 20× ±10 psi
DP50 ±50 ±160 G 0.05 ±10 psi
DP150 ±150 ±350 G 0.02 50 psi
DP300 ±300 ±700 G 0.02 50 psi
[1] FS specification applies to the span of the range. Accuracy includes 1 year stability. [2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability.

 

Compound Pressure
P/N Pressure Range Media Accuracy Pressure Rating
psig bar.g Burst Over Pressure
CP2 ±2 ±0.16 G 0.05% FS 3x 1.2x
CP5 ±5 ±0.35 G 0.02% FS 3x 1.2x
CP10 ±10 ±0.7 G 0.02% FS 3x 1.2x
CP15 ±15 ±1.0 G 0.02% FS 3x 1.2x
CP30 -15 to 30 -1 to 2.0 G 0.02% FS 3x 1.2x
CP50 -15 to 50 -1 to 3.5 G 0.02% FS 3x 1.2x
CP100 -15 to 100 -1 to 7.0 G,L 0.02% FS 3x 1.2x
CP300 -15 to 300 -1 to 20 G,L 0.02% FS 3x 1.2x
CP500 -15 to 500 -1 to 35 G,L 0.02% FS 3x 1.2x
CP600 -15 to 600 -1 to 40 G,L 0.02% FS 3x 1.2x
CP1K -15 to 1,000 -1 to 70 G,L 0.02% FS 3x 1.2x
CP2K -15 to 2,000 -1 to 140 G,L 0.02% FS 3x 1.2x
CP3K -15 to 3,000 -1 to 200 G,L 0.02% FS 3x 1.2x
CP5K -15 to 5,000 -1 to 350 G,L 0.02% FS 3x 1.2x
CP10K -15 to 10,000 -1 to 700 G,L 0.02% FS 2x 1.2x

 

Absolute Pressure
P/N Pressure Range Media Accuracy (%FS) Burst Pressure
psi bar
AP5 5 0.35 G 0.1
AP10 10 0.7 G 0.1
AP15 15 1 G 0.1
AP30 30 2 G 0.1
AP50 50 3.5 G 0.1
AP100 100 7 G , L 0.05 (0.1)
AP300 300 20 G , L 0.05 (0.1)
AP500 500 35 G , L 0.05 (0.1)
AP1K 1000 70 G , L 0.05 (0.1)
AP3K 3000 200 G , L 0.05 (0.1)
AP5K 5000 350 G , L 0.05 (0.1)

 

Precision Sensors[1] – Absolute Pressure
P/N Pressure Range Media Accuracy[2] Pressure Rating
psia bar.a Burst Over Pressure
AP15R 0 to 15 0 to 1 G 0.01% FS 2x 1.2x
AP30R 0 to 30 0 to 2 G 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP50R 0 to 50 0 to 3.5 G 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP100R 0 to 115 0 to 8 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP300R 0 to 315 0 to 21 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP500R 0 to 515 0 to 36 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP1KR 0 to 1,015 0 to 71 G,L 0.01% rdg or 0.003% FS whichever is greater 2x 1.2x
AP2KQ 0 to 2,015 0 to 141 G 0.005% rdg + 0.005% FS 3x 1.1x
AP3KQ 0 to 3,015 0 to 201 G 0.005% rdg + 0.005% FS 3x 1.1x
AP6KQ 0 to 6,000 0 to 400 G,L 0.01% FS 3x 1.2x
AP10KQ 0 to 10,000 0 to 700 G,L 0.01% FS 2x 1.2x
AP15KQ 0 to 15,000 0 to 1000 G,L 0.01% FS 2x 1.2x
AP20KQ 0 to 20,000 0 to 1400 G,L 0.01% FS 2x 1.2x
AP30KQ 0 to 30,000 0 to 2000 G,L 0.02% FS 1.5x 1.1x
AP40KQ 0 to 40,000 0 to 2800 G,L 0.02% FS 1.5x 1.1x
[1] Contact Additel for other range options. [2] Accuracy includes calibration uncertainty, linearity and long-term stability.

 

Barometric Pressure
P/N Pressure Range Media Accuracy Burst Pressure
Low High
BP 60 kPa 110 kPa G 40 Pa