Description
OVERVIEW
A highly integrated multifunction calibrator featuring several patented technologies, the 223A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring pressure, temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. With HART communication capability, the 223A is ideal for calibrating, maintaining, and troubleshooting HART instrumentations. Automation and documentation capabilities make the 223A a turnkey solution.
FEATURES
Sourcing, simulating and measuring pressure, temperature and electrical signals
• Smartphone-like menu and interface make the operation simpler
• Hart Communication capability
• The internal cold junction compensation sensor can be re-calibrated at ice point by user
• Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
APPLICATIOS
• NIST Traceable Calibration with data
• Warranty:
3 years
SPECIFICATIONS
Measurement Accuracy | ||||
---|---|---|---|---|
Range | Resolution | Accuracy | ||
Voltage DC | ±75.0000 mV | 0.1μV | 0.01%RD + 3.75 μV | |
±30.0000 V | 0.1 mV | 0.01%RD + 1.5 mV | ||
Current DC | ± 30.0000 mA | 0.1μA | 0.01%RD + 1.5 μA | |
Resistance | Two-wire | 0 to 400.000 Ω | 1mΩ | 0.02%RD + 0.02 Ω |
Three-wire | 0 to 400.000 Ω | 1mΩ | 0.02%RD + 0.02 Ω | |
Four-wire | 0 to 400.000 Ω | 1mΩ | 0.01%RD + 0.02 Ω | |
Two-wire | 0 to 4000.00 Ω | 10mΩ | 0.02%RD + 0.2 Ω | |
Three-wire | 0 to 4000.00 Ω | 10mΩ | 0.02%RD + 0.2 Ω | |
Four-wire | 0 to 4000.00 Ω | 10mΩ | 0.01%RD + 0.2 Ω | |
Frequency | 1 to 50000.0 Hz | 0.1Hz | 0.005%RD + 1 Hz | |
Pulse | 0 to 999999 | 1 | N/A | |
Limit Switch | For the contact with potential, the voltage within the range 3V to 24V. |
Source Accuracy | |||
---|---|---|---|
Voltage DC | -10.000 to 75.000mV | 1μV | 0.02%RD + 4.25 μV |
0 to 12.0000 V | 0.1mV | 0.02%RD + 0.6 mV | |
Current DC | 0 to 22.000 mA | 1μA | 0.02%RD + 1.1 μA |
Resistance | 1 to 400.00 Ω | 10mΩ | 0.02%RD + 0.02 Ω |
1 to 4000.0 Ω | 100mΩ | 0.03%RD + 0.4 Ω | |
Frequency | 0 to 50000.0 Hz | 0.1Hz | 0.005%RD + 1 Hz |
Pulse | 0 to 999999 | 1 | N/A |
DC24V | N/A | N/A | 0.5V |
Thermocouple Measurement and Source Accuracy | |||||
---|---|---|---|---|---|
Measure and Simulate | Standard | Temperature Range (oC) | Accuracy (oC) | ||
Measure | Source | ||||
S | IEC 584 | -50 to 1768 | -50 to400 | 1 | 1.1 |
400 to 1000 | 0.6 | 0.6 | |||
1000 to1768 | 0.7 | 0.8 | |||
R | IEC 584 | -50 to 1768 | -50 to 200 | 1.4 | 1.4 |
200 to 500 | 0.6 | 0.6 | |||
500 to 1768 | 0.6 | 0.7 | |||
B | IEC 584 | 0 to 1820 | 50 to 450 | 3.8 | 3.8 |
450 to 800 | 0.9 | 0.9 | |||
800 to 1820 | 0.6 | 0.7 | |||
K | IEC 584 | -270 to 1372 | -250 to -200 | 1 | 1.1 |
-200 to -100 | 0.4 | 0.5 | |||
-100 to 600 | 0.3 | 0.3 | |||
600 to 1372 | 0.4 | 0.5 | |||
N | IEC 584 | -270 to 1300 | -250 to -200 | 1.5 | 1.6 |
-200 to -100 | 0.5 | 0.6 | |||
-100 to 1300 | 0.4 | 0.5 | |||
E | IEC 584 | -270 to 1000 | -250 to -200 | 0.6 | 0.7 |
-200 to -100 | 0.3 | 0.3 | |||
-100 to 0 | 0.2 | 0.2 | |||
0 to 700 | 0.2 | 0.3 | |||
700 to 1000 | 0.2 | 0.4 | |||
J | IEC 584 | -270 to 1200 | -210 to -100 | 0.3 | 0.3 |
-100 to 1200 | 0.3 | 0.4 | |||
T | IEC 584 | -270 to 400 | -250 to -200 | 0.8 | 0.9 |
-200 to 0 | 0.4 | 0.4 | |||
0 to 400 | 0.2 | 0.2 | |||
C | ASTM E988 | 0 to 2315 | 0 to 1000 | 0.5 | 0.5 |
1000 to 1800 | 0.7 | 0.9 | |||
1800 to 2315 | 1 | 1.4 | |||
D | ASTM E988 | 0 to 2320 | 0 to 100 | 0.5 | 0.5 |
100 to 1100 | 0.4 | 0.5 | |||
1100 to 2000 | 0.6 | 0.9 | |||
2000 to 2320 | 0.9 | 1.3 | |||
G | ASTM E1751 | 0 to 2315 | 0 to 200 | 2.4 | 2.4 |
200 to 400 | 0.5 | 0.5 | |||
400 to 1400 | 0.4 | 0.5 | |||
1400 to 2315 | 0.7 | 1 | |||
L | DIN43710 | -200 to 900 | -200 to -100 | 0.2 | 0.3 |
-100 to 400 | 0.2 | 0.2 | |||
400 to 900 | 0.2 | 0.3 | |||
U | DIN43710 | -200 to 600 | -200 to 0 | 0.4 | 0.4 |
0 to 600 | 0.2 | 0.3 | |||
*Accuracy with external cold junction; for internal cold junction add 0.1°C (k=2) |
Measurement Accuracy | ||||||
---|---|---|---|---|---|---|
Measure and Simulate | Standard | Temperature Range (°C) | Accuracy (°C) | |||
Measure (2W/3W) | Measure (4W) | Source | ||||
Pt10(385) | IEC 751 | -200 to 850 | -100 to 200 | 0.65 | 0.6 | 0.65 |
200 to 600 | 0.82 | 0.72 | 0.82 | |||
600 to 850 | 0.96 | 0.82 | 0.96 | |||
Pt100(385) | IEC 751 | -200 to 850 | -100 to 200 | 0.15 | 0.1 | 0.15 |
200 to 600 | 0.26 | 0.16 | 0.26 | |||
600 to 850 | 0.34 | 0.2 | 0.34 | |||
Pt100(3916) | JIS 1604 | -200 to 850 | -100 to 200 | 0.15 | 0.1 | 0.15 |
200 to 600 | 0.26 | 0.16 | 0.26 | |||
600 to 850 | 0.33 | 0.2 | 0.33 | |||
Pt100(3926) | Minco Application Aid #18 | -200 to 850 | -100 to 200 | 0.15 | 0.1 | 0.15 |
200 to 600 | 0.26 | 0.16 | 0.26 | |||
600 to 850 | 0.33 | 0.2 | 0.33 | |||
Pt500(385) | IEC 751 | -200 to 850 | -100 to 200 | 0.2 | 0.16 | 0.36 |
200 to 600 | 0.32 | 0.22 | 0.54 | |||
600 to 850 | 0.4 | 0.27 | 0.67 | |||
Pt1000(385) | IEC 751 | -200 to 850 | -100 to 200 | 0.1 | 0.05 | 0.25 |
200 to 600 | 0.2 | 0.1 | 0.42 | |||
600 to 850 | 0.27 | 0.14 | 0.54 | |||
Cu10(427) | Minco Application Aid #18 | -100 to 260 | -100 to 260 | 0.61 | 0.56 | 0.61 |
Cu50(428) | GOST 6651-94 | -50 to 150 | -50 to 150 | 0.17 | 0.13 | 0.17 |
Cu100(428) | GOST 6651-94 | -50 to 150 | -50 to 150 | 0.12 | 0.09 | 0.12 |
Ni120(672) | Edison curve #7 | -100 to 260 | -100 to 260 | 0.07 | 0.05 | 0.07 |
Ni100(618) | DIN 43760 | -100 to 260 | -100 to 260 | 0.08 | 0.06 | 0.08 |
General Specifications | ||
---|---|---|
Operating Temperature | -10°C to 50°C | |
Storage Temperature | -20°C to 60°C | |
Humidity | <90%, non-condensing | |
European Compliance | CE Mark | |
Display | 3.5 inch TFT color screen | |
Electrical Connection | Ø4mm sockets and flat mini-jack thermocouple socket | |
RS232 Interface | Standard RS232-DB9 socket | |
Size | 3.9″ x 7.6″ x 2.0″ (100mm x 192mm x 52mm) | |
Weight | 1.6 lb (0.7 kg) | |
Power Supply | Polymer Li-ion rechargeable battery,or 10V DC adaptor | |
Battery | Rechargeable Li-ion battery (included) | |
Battery Life | 15 hours uninterrupted use | |
Battery life will be reduced when 24V is applied | ||
Battery Charge | 110V/220V external power adapter (included) | |
Pressure Specifications (222A & 223A) | The 160A series Intelligent Digital Pressure Modules are available for gauge, vacuum and absolute pressure from -15 psi to 10,000 psi (-1 bar to 700 bar). Accuracy from 0.02% FS includes operation over 14°F to 122°F (-10°C to 50°C), one year stability and calibration uncertainty. For detail specification refer to pressure modules datasheet. |